Low-cost particulate matter sensors in Turin

Six low-cost PM sensors compared with the ARPA Piemonte reference station Torino–Rubino, 10–21 November 2026. Master's thesis, Politecnico di Torino.

6
sensors: SEN55, SEN54, SPS30, PMS5003, PMS7003, SDS011
valid hours (co-location + stationary)

Hourly concentrations vs reference

Hourly means. Co-location hours (next to the station) and stationary hours (about 5 km away) are both shown; gaps are periods without measurements. Calibration: simple linear regression fitted on the co-location hours only.

SensorR²SlopeRMSE rawRMSE calibrated

Error on the stationary (test) hours, in µg/m³. The US EPA performance target for PM2.5 is RMSE ≤ 7 µg/m³.